Journal Information
Vol. 88. Issue 2.
Pages 220-227 (March - April 2022)
Visits
4241
Vol. 88. Issue 2.
Pages 220-227 (March - April 2022)
Original article
Open Access
Grayscale, subjective color Doppler, combined grayscale with subjective color Doppler in predicting thyroid carcinoma: a retrospective analysis
Visits
4241
Minxin Wanga, Xiaoting Wanga, Hongsheng Zhangb,
Corresponding author
superman_li@126.com

Corresponding author.
a Weihai Central Hospital, Department of Ultrasound, Shandong, China
b Weihai Central Hospital, Department of Imaging, Shandong, China
This item has received

Under a Creative Commons license
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Figures (6)
Show moreShow less
Tables (3)
Table 1. The demographical and clinical conditions of the enrolled patients.
Table 2. Diagnostic performance of ultrasound techniques.
Table 3. Association of false predictive due to imaging modalities values and histopathological features.
Show moreShow less
Abstract
Introduction

Fine needle aspiration cytology is preferred for thyroid nodules preoperatively, but has disadvantages of false-negative and false-positive results.

Objective

To compare the diagnostic performance of grayscale ultrasound, subjective color Doppler ultrasound, and combined features of grayscale ultrasound and subjective color Doppler ultrasound in predicting thyroid carcinoma, using results of the fine needle aspiration cytology as the reference standard.

Methods

Data from gray-scale ultrasound images, subjective color Doppler ultrasound images, and the fine needle aspiration cytology of 325 nodules of 250 patients (age ≥ 18 years) were collected and analyzed. Hypo-echogenicity than adjacent strap muscle, micro-lobulated or irregular margins, micro- or mixed calcifications, and taller-than-wide shapes were considered as a suspicious malignant nodule in grayscale ultrasound. Marked vascularity was considered as a suspicious malignant nodule in color Doppler ultrasound. The Bethesda system for classification of thyroid nodules was used for cytopathology.

Results

With respect to the results of fine-needle aspiration cytology for detecting suspicious malignant nodules, for grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler ultrasound, sensitivities were 0.564, 0.600 and 0.691, respectively and accuracies were 0.926, 0.919 and 0.959, respectively. Suspicious malignant nodules detectability for grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler ultrasound were 0.09–0.56 diagnostic confidence, 0.08–0.61 diagnostic confidence, and 0.063–0.7 diagnostic confidence, respectively.

Conclusions

The combined gray-scale with subjective color Doppler ultrasound-guided fine-needle aspiration biopsies are recommended for the diagnosis of thyroid carcinoma.

Level of Evidence: III.

Keywords:
Color Doppler ultrasound
Fine-needle aspiration cytology
Grayscale ultrasound
Suspicious malignant nodule
Thyroid carcinoma
Full Text
Introduction

Thyroid carcinoma is a very common malignancy in clinical practice.1 Imaging modalities make it possible to increase the detection of thyroid nodules.2 Diagnostic modalities can effectively predict the presence or absence of nodule(s) in neck imaging in two out of three patients, and can help in clinical evaluation of thyroid nodules.3 Fine needle aspiration cytology is preferred for thyroid nodules preoperatively1 but has disadvantages of possible false-negative and false-positive results. Florid atypia is responsible for false-negative and positive results in fine-needle aspiration cytology,4 while real-time ultrasound can predict size, numbers, and site(s) of thyroid nodules.5

The 2015 American thyroid association management guidelines recommended gray-scale ultrasound for thyroid nodules6 but its features of malignant and benign nodules are overlapped.7 While color Doppler ultrasound allows visualization of minute vessels with slow blood velocity to predict characteristics of the tumor8 and improves the sensitivity of grayscale ultrasound1 but a prospective study reported that the performance of grayscale ultrasound combined with color Doppler does not improve diagnostic performance of the gray-scale ultrasound.9 There exists no clear consensus available for benign and suspicious nodules in color Doppler ultrasound examinations.10

The objective of the study was to compare the diagnostic performance of the grayscale ultrasound, subjective color Doppler ultrasound, and combined features of grayscale ultrasound and subjective color Doppler ultrasound in predicting thyroid carcinoma, using results of fine-needle aspiration cytology as the reference standard.

MethodsEthics approval and consent to participate

The designed protocol (WCH/CL/31/19 dated 22 October 2019) was approved by the institutional review board and the medical council of the country. The study reporting adheres to the law of the country. An informed consent form was signed by all patients regarding diagnosis and the publication of the study, including personal data and images irrespective of time and language during hospitalization. Approval was obtained from competing authorities before the collection of data.

Study population

Gray-scale ultrasound and color Doppler ultrasound images of 325 nodules of 250 patients (age ≥ 18 years) admitted from 15 January 2018 to 10 September 2019 at the parent hospital and the referring hospitals were collected after institutional approval. All patients had been subjected to fine-needle aspiration cytology during their diagnosis and treatment of thyroid carcinoma (Fig. 1). Female patient numbers exceeded that of male patients. The other demographical and clinical conditions of the enrolled patients are presented in Table 1.

Figure 1.

Flow diagram of the study.

(0.15MB).
Table 1.

The demographical and clinical conditions of the enrolled patients.

CharacteristicsValue 
Nodules subjected to analysis325 
Patients included in the analysis250 
Age (years)Minimum  19 
Maximum  71 
Mean ± SD  48.55 ± 7.54 
GenderMale  53 (21) 
Female  197 (79) 
EthnicityHan Chinese  227 (91) 
Mongolian  20 (8) 
Tibetan  3 (1) 
Nodules per patient mean (range)1.3 (1–4) 
Family history of thyroid carcinoma12 (5) 

Categorical data demonstrate as frequency (percentage) and continuous data demonstrate as mean ± SD.

Ultrasound examinations

All patients were instructed to lay down on the bed in a supine position using Versana Premier (GE Healthcare system, Chicago, IL, USA) and EPIQ Elite (Philips Medical System, Chicago, IL, USA) equipment with 12 MHz linear probe, gray-scale and color Doppler images were derived in the single setting by the radiologists (a minimum of 3 years of experience of thyroid images) of the institutes. Standard transverse and longitudinal ultrasound images were evaluated.

Image analysis

In the grayscale ultrasound, marked hypoechogenicity than adjacent strap muscle (Fig. 2A), micro-lobulated (Fig. 2B) or irregular margins (Fig. 2C), micro (Fig. 2D) or mixed calcifications (Fig. 2E), and taller-than-wide shapes (anteroposterior diameter longer than the transverse diameter on a transverse/longitudinal plane) (Fig. 2F) were considered as a suspicious malignant nodule. For thyroid nodules, the absence of the above features was considered as benign.11

Figure 2.

Grayscale ultrasound diagnoses of the thyroid nodules. A, Hypoechogenicity than adjacent strap muscle, B, Micro-lobulated, C, Irregular margins, D, Microcalcifications, E, Mixed-calcifications, F, The taller-than-wide shape in greater anteroposterior dimension.

(0.06MB).

In color Doppler images, avascularity (Fig. 3A) or peri-nodular flow (Fig. 3B) (vascularity ≤ 25% of the nodule circumference) was considered as a benign nodule and marked vascularity (flow pattern was greater than that of surrounding part) (Fig. 3C) was considered as suspicious for malignant nodules.1

Figure 3.

Subjective color Doppler ultrasound diagnosis. A, Avascularity; B, Vascularity ≤ 25% of the nodule circumference; C, Flow pattern is greater than that of the surrounding part.

(0.07MB).

Ultrasound technologists (a minimum of 5 years of experience of thyroid imaging) of the institutes were involved in the image analyses.

Fine needle aspiration biopsies

In a supine position, the skin of the neck was sterilized with antiseptics. A 25G needle was used to puncture the skin and material from the thyroid was collected a in 10 mL aspirator. The collected sample was sent to the pathological laboratory for analysis. Biopsy evaluation was performed by pathologists (a minimum of 3 years of experience) of the institutes.

Pathology

Biopsy samples were analyzed by cytopathologists (a minimum of 3 years of experience) of the institutes. The grading of lesions was performed as per the 2017 Bethesda System for the classification of thyroid nodules.12 True papillae (Fig. 4A), nuclear pseudo inclusions (Fig. 4B), mild nuclear irregularity (Fig. 4C), and psammoma bodies (Fig. 4D) in histopathological features were considered as suspicious malignant nodules. If these features were absent, they were considered benign nodules.13

Figure 4.

Histopathological features of suspicious malignant nodules. A, True papillae; B, Nuclear pseudo inclusions (black arrow); C, Mild nuclear irregularity (white arrow); and D, Psammoma bodies (black circle) (Hematoxylin & Eosin staining).

(0.15MB).
Diagnostic parameters

The ratio of true positive suspicious malignant nodules detected through imaging modality to those detected through fine needle aspiration cytology considered as sensitivity. The ratio of true positive benign nodules detected through imaging modality to those detected through fine needle aspiration cytology was considered as accuracy.

Beneficial score analysis

Beneficial score analysis for grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler for decision-making in fine needle aspiration biopsies was calculated as per Eqs. (1) and (2).14

True positive suspicious malignant nodule: suspicious malignant nodule detected by imaging modality and detected by fine-needle aspiration cytopathology.

False-positive suspicious malignant nodule: suspicious malignant nodule detected by imaging modality but not detected by fine-needle aspiration cytopathology.

Statistical analyses

InStat version Window 3.01, GraphPad, San Diego, CA, USA was used for statistical analyses purpose. For categorical variables, the Chi-square Independence test was performed and for a continuous variable15 and an independent two-sample t-test was performed.9 Univariate following multivariate analysis was performed for association of false predictive values and histopathological features. Results were considered significant at a 95% Confidence Level.

Results

There was no significant difference between nodule size detected by gray-scale ultrasound and subjective color Doppler ultrasound (1.54 ± 0.16 cm vs. 1.56 ± 0.17 cm, p = 0.872) (Fig. 5).

Figure 5.

Nodule size distributions by ultrasound examinations. Data demonstrate mean ± SD. Data of 325 nodules were used for analysis. An Independent two-sample t-test was performed for statistical analysis. A p < 0.05 was considered significant.

(0.05MB).
Diagnostic parameters

With respect to the results of fine-needle aspiration cytology for detecting suspicious malignant nodules, grayscale ultrasound, subjective color Doppler ultrasound, and combined gray-scale with subjective color Doppler, sensitivities were 0.564, 0.600, and 0.691, respectively and accuracies were 0.926, 0.919, and 0.959, respectively. There was no significant difference between the combined gray-scale with subjective color Doppler ultrasound and fine-needle aspiration cytopathology for true positive suspicious malignant nodules (p = 0.073) and true positive benign nodules (p = 0.314) but it reported significant numbers of false-positive suspicious malignant nodules (p < 0.0001) and false-positive benign nodules (p = 0.003). The detailed diagnostic parameters are presented in Table 2.

Table 2.

Diagnostic performance of ultrasound techniques.

Parameters  Fine-needle aspiration cytology  Grayscale ultrasoundSubjective color Doppler ultrasoundCombined grayscale with subjective color Doppler
Total numbers of nodules analyzed  325  325  ap-Value  325  ap-Value  325  ap-Value 
True positive suspicious malignant nodules detected  55 (17)  31 (10)  0.008  33 (10)  0.016  38 (12)b  0.073 
True positive benign nodules detected  270 (83)  250 (77)b  0.062  248 (76)  0.041  259 (80)b  0.314 
False positive suspicious malignant nodules detected  0 (0)  24 (7)  <0.0001  22 (7)  <0.0001  17 (5)  <0.0001 
False positive benign nodules detected  0 (0)  20 (6)  <0.0001  22 (7)  <0.0001  11 (3)  0.003 
Sensitivity  0.564  0.008  0.600  0.016  0.691b  0.073 
Accuracy  0.926b  0.062  0.919b  0.067  0.959b  0.314 

Data are shown as frequency (percentage).

A Chi-Square independence test was performed for statistical analysis.

A p < 0.05 was considered significant.

a

With respect to fine-needle aspiration cytology.

b

Insignificant difference with respect to fine-needle aspiration cytology.

Beneficial score analysis

Suspicious malignant nodule detectability for grayscale ultrasound, subjective color Doppler ultrasound, and subjective combined gray-scale with color Doppler ultrasound was 0.09–0.56 diagnostic confidence, 0.08–0.61 diagnostic confidence, and 0.063–0.7 diagnostic confidence, respectively (Fig. 6). Above 0.56, 0.61 and 0.7 diagnostic confidence grayscale ultrasound, subjective color Doppler ultrasound, and subjective combined gray-scale with color Doppler ultrasound had no diagnostic potential respectively and below 0.09, 0.08 and 0.063 diagnostic potential grayscale ultrasound, subjective color Doppler ultrasound, and subjective combined gray-scale with color Doppler ultrasound had the risk of overdiagnosis respectively.

Figure 6.

Beneficial score analysis. Ultrasound technologists (a minimum of 5 years of experience of thyroid images) of the institutes were involved in the image analyses.

(0.18MB).
Pathological parameters detected by ultrasound imaging

Univariate analysis reported that gray-scale and subjective color Doppler ultrasound decreased false predictive values of all types of histopathological features (p > 0.0001 for all). However, multivariate analysis reported that gray-scale ultrasound decreased false predictive values for mild nuclear irregularity (p = 0.051) and psammoma bodies (p = 0.053). Subjective color Doppler ultrasound decreased false predictive values for nuclear pseudo inclusions (p = 0.052) and mild nuclear irregularity (p = 0.052). The combined grayscale with subjective color Doppler decreased false predictive values for nuclear pseudo- inclusions (p = 0.052), mild nuclear irregularity (p = 0.053), and psammoma bodies (p = 0.055). However, ultrasound imaging failed in reduction of false predictive values for true papillae (p < 0.05 for all modalities). The detailed association of false prediction due to imaging modalities values and histopathological features reported in fine-needle aspiration cytopathology are reported in Table 3.

Table 3.

Association of false predictive due to imaging modalities values and histopathological features.

Ultrasound technique  Grayscale ultrasoundSubjective color Doppler ultrasoundCombined grayscale with subjective color Doppler
False negative predictive values  444428
Histopathological parameters  OR  95% CL  p-Value  Odd ratio  95% CL  p-Value  OR  95% CL  p-Value 
True papillae  0.72  0.78–0.89  0.043a  0.73  0.77–0.81  0.039a  0.61  0.57–0.82  0.042a 
Nuclear pseudo inclusions  0.61  0.77–0.91  0.042a  0.74  0.72–0.86  0.051  0.72  0.71–0.82  0.052 
Mild nuclear irregularity  0.62  0.56–0.92  0.051  0.65  0.79–0.85  0.052  0.73  0.73–0.85  0.053 
Psammoma bodies  0.69  0.62–0.78  0.053  0.76  0.76–0.91  0.048a  0.71  0.71–0.89  0.055 

OR, odd ratio, 95% CL, 95% confidence limit.

Results of true positive a predictive value was considered reference standard. Multivariate regression analysis. A p < 0.05 was considered significant.

a

Significant parameter of histopathology responsible for false predictive value.

Discussion

Grayscale ultrasound, subjective color Doppler ultrasound, combined gray-scale with color subjective Doppler ultrasound had 0.564, 0.6 and 0.691 sensitivities. The addition of subjective color Doppler to grayscale moderately increases the sensitivity of diagnosis. The results of the study are consistent with prospective studies,1,16–18 quantitative analysis of color Doppler ultrasound,19 and cross-sectional studies2,15 but not consistent with prospective studies.9,10,20 The reason behind contradicted results is that there exists an absence of universal authoritative guidelines that indicate a specific vascularity pattern in ultrasound examinations.9 Also, visual assessment of nodular vascularity is subjective and has inter- and intra-observer variations.17 Angiogenesis and proliferation of vessels in suspicious malignant nodule increases vascularity in the color Doppler ultrasound.19 The current study recommended a combined gray-scale with subjective color Doppler ultrasound guidance for the performance of fine-needle aspiration biopsies.

The grayscale ultrasound had comparatively higher false negative and false positive suspicious malignant nodules. The results of the current study were parallel with prospective studies.9,21 The follicular variant of papillary carcinoma resembles benign nodules in grayscale ultrasound and mixed- calcifications of benign lesions were considered as a suspicious malignant nodule.1 In subjective color Doppler, there are fewer chances of false-negative malignancy because the suspicious malignancy was detected on the basis of vascularity.

With respect to fine-needle aspiration biopsies, grayscale ultrasound, subjective color Doppler ultrasound, and the combined subjective gray-scale with color Doppler ultrasound reported significant false-positive suspicious malignant nodules (p < 0.0001 for all). The results of the study were consistent with retrospective analysis,14 prospective studies,1,9 and cross-sectional study.15 Besides suspicious malignant nodules, thyroid calcifications are reported in benign nodules and conventional ultrasound is unable to differentiate calcified benign colloidal echogenicities from micro- or mixed-calcifications of suspicious malignant nodules.18 Therefore, ultrasound techniques reported false-positive suspicious malignant nodules.

Accuracies of combined gray-scale with color Doppler ultrasound were 0.959. The results of the study were parallel with prospective studies.9,22 The distribution inside nodules and adjacent thyroid parenchyma are possible to study in better detail by color Doppler ultrasound. Therefore, the addition of color Doppler ultrasound increases the accuracy of gray-scale ultrasound.

The combined subjective gray-scale with color Doppler ultrasound imaging failed in reduction of false predictive values for true papillae type of suspicious malignant thyroid carcinoma. True papillae are a major type of thyroid carcinoma. This is small-sized and has no posterior acoustic shadowing. Conventional ultrasound has difficulties in detection of true papillae thyroid carcinoma.18 Shear-wave ultrasound elastography could be useful in such conditions.

In the limitations of the study, for example, ultrasound elastography was not performed. Elastography only improves visualization of tissue elasticity or stiffness properties but cannot improve the diagnosis.23 The results of the histopathology of the surgical specimen were not included in the analyses. Grading systems have the advantage of allowing different criteria to be applied to each grade in order to decide whether to perform fine-needle aspiration biopsies. For example, different size cut-offs can be applied to different grades but in the current study, the suspicious malignant detectability did not determine the size of the nodules. An experienced radiologist is required for image analysis in thyroid carcinoma7 but the study did not perform inter-or intra-observer agreements. In grayscale ultrasound echogenicity, lobulation, calcifications, and shape were used to rule out suspicious malignancy. The other features, like spongiform and cystic characteristics, were not used to rule out suspicious malignancy. This was the main reason for the reporting of significant numbers of false-positive benign nodules for grayscale ultrasound (p < 0.0001), subjective color Doppler ultrasound (p < 0.0001), and subjective combined gray-scale with color Doppler ultrasound (p = 0.003). Also, the study did not use a pulsatility index, mean systolic velocity, and resistive index for diagnosis of malignancy, but these are not useful parameters for detecting suspicious malignant nodules.15 If the combined grayscale with subjective color Doppler ultrasound may increase sensitivity and accuracy but decreases specificity but data regarding specificity did not evaluate.

Conclusions

Grayscale ultrasound and subjective color Doppler ultrasound evaluations are both non-invasive and useful diagnostic techniques in the diagnosis of thyroid suspicious malignant nodules. Subjective color Doppler ultrasound may increase the sensitivity and accuracy of grayscale ultrasound in the detection of suspicious malignant thyroid nodules. The combined grayscale with subjective color Doppler ultrasound-guided fine-needle aspiration biopsies is recommended in the diagnosis of thyroid carcinoma.

Compliance with ethics standard

The designed protocol (WCH/CL/31/19 dated 22 October 2019) was approved by the Weihai Central Hospital review board and the medical council of China.

Availability of data and materials

The datasets used and analyzed during the current study available from the corresponding author on reasonable request.

Conflicts of interest

The authors declare no conflicts of interest.

Acknowledgments

The authors are thankful for the medical and non-medical staff of the Weihai Central Hospital, Weihai, Shandong, China.

References
[1]
W. Phuttharak, C. Somboonporn, G. Hongdomnern.
Diagnostic performance of gray-scale versus combined gray-scale with colour Doppler ultrasonography in the diagnosis of malignancy in thyroid nodules.
Asian Pac J Cancer Prev, 10 (2009), pp. 759-764
[2]
M. Salehi, F. Nalaini, B. Izadi, K. Setayeshi, M. Rezaei, S.N. Naseri.
Gray-scale vs. color Doppler ultrasound in cold thyroid nodules.
Glob J Health Sci, 7 (2014), pp. 147-152
[3]
G.S. Manso, M.J. Velasco Marcos.
Review of the current value of ultrasonography in the characterization of thyroid nodules.
Radiologia, 57 (2015), pp. 248-258
[4]
D.C. Malheiros, S. Canberk, D.N. Poller, F. Schmitt.
Thyroid FNAC: causes of false-positive results.
Cytopathology, 29 (2018), pp. 407-417
[5]
Y. Dong, M. Mao, W. Zhan, J. Zhou, W. Zhou, J. Yao, et al.
Size and ultrasound features affecting results of ultrasound-guided fine-needle aspiration of thyroid nodules.
J Ultrasound Med, 37 (2018), pp. 1367-1377
[6]
B.R. Haugen, E.K. Alexander, K.C. Bible, G.M. Doherty, S.J. Mandel, Y.E. Nikiforov, et al.
2015 American Thyroid Association Management Guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association Guidelines Task Force on thyroid nodules and differentiated thyroid cancer.
Thyroid, 26 (2016), pp. 1-133
[7]
J.P. Brito, M.R. Gionfriddo, A. Al Nofal, K.R. Boehmer, A.L. Leppin, C. Reading, et al.
The accuracy of thyroid nodule ultrasound to predict thyroid cancer: systematic review and meta-analysis.
J Clin Endocrinol Metab, 99 (2014), pp. 1253-1263
[8]
Y. Ma, G. Li, J. Li, W.D. Ren.
The diagnostic value of Superb Microvascular Imaging (SMI) in detecting blood flow signals of breast lesions: a preliminary study comparing SMI to color Doppler flow imaging.
[9]
J.H. Yoon, E.K. Kim, J.Y. Kwak, V.Y. Park, H.J. Moon.
Application of various additional imaging techniques for thyroid ultrasound: direct comparison of combined various elastography and Doppler parameters to gray-scale ultrasound in differential diagnosis of thyroid nodules.
Ultrasound Med Biol, 44 (2018), pp. 1679-1686
[10]
P.W. Rosario, A.L. Silva, M.A. Borges, M.R. Calsolari.
Is Doppler ultrasound of additional value to gray-scale ultrasound in differentiating malignant and benign thyroid nodules?.
Arch Endocrinol Metab, 59 (2015), pp. 79-83
[11]
J.H. Yoon, J.Y. Kwak, H.J. Moon, M.J. Kim, E.K. Kim.
The diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy and the sonographic differences between benign and malignant thyroid nodules 3 cm or larger.
Thyroid, 21 (2011), pp. 993-1000
[12]
A.A. Renshaw, E.W. Gould.
Incidence and significance of true papillae in thyroid fine needle aspiration.
Diagn Cytopathol, 45 (2017), pp. 689-692
[13]
E.S. Cibas, S.Z. Ali.
The 2017 Bethesda System for reporting thyroid cytopathology.
Thyroid, 27 (2017), pp. 1341-1346
[14]
W. Tao, Z. Qingjun, Z. Wei, Z. Fang, Z. Lei, N. Yuanyuan, et al.
Computed tomography versus ultrasound/fine needleaspiration biopsy in differential diagnosis of thyroidnodules: a retrospective analysis.
Braz J Otorhinolaryngol, (2019),
[15]
S. Kalantari.
The diagnostic value of color Doppler ultrasonography in predicting thyroid nodules malignancy.
Int Tinnitus J, 22 (2018), pp. 35-39
[16]
F. Stacul, M. Bertolotto, F. De Gobbis, L. Calderan, V. Cioffi, A. Romano, et al.
US, colour-Doppler US and fine-needle aspiration biopsy in the diagnosis of thyroid nodules.
Radiol Med, 112 (2007), pp. 751-762
[17]
F.N. Baig, J.T. Lunenburg, S.Y. Liu, S.P. Yip, H.K.W. Law, M. Ying.
Computer-aided assessment of regional vascularity of thyroid nodules for prediction of malignancy.
[18]
D. Yildirim, C. Samanci, F.E. Ustabasioglu, D. Alis, B. Colakoglu, A. Bakır, et al.
A dilemma at gray scale thyroid ultrasound: microcalcification or not? Differentiation with acoustic radiation force impulse imaging-virtual touch imaging.
Med Ultrason, 18 (2016), pp. 452-456
[19]
L.R. Sultan, H. Xiong, H.M. Zafar, S.M. Schultz, J.E. Langer, C.M. Sehgal.
Vascularity assessment of thyroid nodules by quantitative color Doppler ultrasound.
Ultrasound Med Biol, 41 (2015), pp. 1287-1293
[20]
J.J. Ma, H. Ding, B.H. Xu, C. Xu, L.J. Song, B.J. Huang, et al.
Diagnostic performances of various gray-scale, color Doppler, and contrast-enhanced ultrasonography findings in predicting malignant thyroid nodules.
Thyroid, 24 (2014), pp. 355-363
[21]
Q. Yu, T. Jiang, A. Zhou, L. Zhang, C. Zhang, P. Xu.
Computer-aided diagnosis of malignant or benign thyroid nodes based on ultrasound images.
Eur Arch Otorhinolaryngol, 274 (2017), pp. 2891-2897
[22]
R. Lu, Y. Meng, Y. Zhang, W. Zhao, X. Wang, M. Jin, et al.
Superb Microvascular Imaging (SMI) compared with conventional ultrasound for evaluating thyroid nodules.
BMC Med Imaging, 17 (2017), pp. 65
[23]
P. Machado, S. Segal, A. Lyshchik, F. Forsberg.
A novel microvascular flow technique: Initial results in thyroids.
Ultrasound Q, 32 (2016), pp. 67-74

Peer Review under the responsibility of Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial.

Copyright © 2020. Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial
Idiomas
Brazilian Journal of Otorhinolaryngology (English Edition)
Article options
Tools
en pt
Announcement Nota importante
Articles submitted as of May 1, 2022, which are accepted for publication will be subject to a fee (Article Publishing Charge, APC) payment by the author or research funder to cover the costs associated with publication. By submitting the manuscript to this journal, the authors agree to these terms. All manuscripts must be submitted in English.. Os artigos submetidos a partir de 1º de maio de 2022, que forem aceitos para publicação estarão sujeitos a uma taxa (Article Publishing Charge, APC) a ser paga pelo autor para cobrir os custos associados à publicação. Ao submeterem o manuscrito a esta revista, os autores concordam com esses termos. Todos os manuscritos devem ser submetidos em inglês.